1.
Arq. bras. med. vet. zootec. (Online) ; 69(4): 807-814, jul.-ago. 2017. ilus, tab
Article in Portuguese | LILACS, VETINDEX | ID: biblio-876516

ABSTRACT

As lesões traumáticas dos membros que resultam em secções tendíneas são problemas comuns na clínica equina. Diversas complicações têm sido associadas à reparação dos tendões nessa espécie. O objetivo do presente trabalho foi avaliar biomecanicamente dois padrões de sutura e dois diferentes materiais aplicados às tenorrafias. Vinte e quatro peças de tendão flexor digital profundo de equinos foram seccionadas e suturadas em padrão locking loop duplo (grupo 1, com polipropileno; grupo 2, com poliglactina) ou em padrão locking loop simples associado à sutura de epitendão (grupo 3, com polipropileno; grupo 4, com poliglactina). Os corpos de prova foram submetidos a ensaios mecânicos de tração, em que se determinaram valores de força mínima, força máxima e pico de força, além do afastamento observado entre os cotos durante o pico máximo de força. Para avaliação dos resultados, foram utilizados os métodos ANOVA e os não paramétricos de Kruskal-Wallis e Mann-Whitney (P<0,05). Os maiores valores de força máxima foram documentados no grupo 3. Os valores de força mínima foram maiores nos grupos 3 e 4 que nos grupos 1 e 2, mas não diferiram significativamente entre os grupos 3 e 4. Os valores de pico de força foram maiores nos grupos 1 e 2 que no grupo 4, mas não diferiram significativamente no grupo 3. O afastamento foi maior nos grupos 1 e 2 quando comparados aos grupos 3 e 4. O padrão locking loop simples, com sutura de epitendão, atingiu maior resistência quando avaliado afastamento de até 3 milímetros entre os cotos tendíneos, sendo considerado padrão de escolha para aplicação clínica, tendo em vista os resultados obtidos neste trabalho.(AU)


Traumatic distal limb injuries resulting in tendon rupture are common in equine practice. Several complications have been associated with tendon repair in horses. The aim of this study was to compare the biomechanical properties of two tenorrhaphy techniques using two different suture materials. Twenty-four equine deep digital flexor tendon specimens were transected and sutured with the double locking loop pattern (polypropylene, group 1; polyglactin, group 2) or the single locking loop pattern with peripheral epitendon suture (polypropylene, group 3; polyglactin, group 4). Specimens were submitted to mechanical strain testing. Maximum, minimum and peak strain, and maximum, minimum and peak gap formation were evaluated. ANOVA and the non-parametric Kruskal-Wallis and Mann-Whitney tests were used (P<0.05). Higher maximum strength values were documented in group 3. Minimum strength values were higher in groups 3 and 4 than 1 and 2, but did not differ significantly between groups 3 and 4. Peak strength values were higher in groups 1 and 2 than 4, but did not differ significantly from group 3. Gap formation was greater in groups 1 and 2 than 3 and 4. The single locking loop pattern with epitendon suture performed with polypropylene had greater resilience, yielded lesser gap formation (3 mm) and is the pattern of choice for clinical application based on the results of this study.(AU)


Subject(s)
Animals , Horses/surgery , Mechanical Phenomena , Suture Techniques/veterinary , Sutures/veterinary , Tendons/surgery
2.
Arq. bras. med. vet. zootec ; 68(6): 1531-1538, nov.-dez. 2016. tab, ilus
Article in English | LILACS, VETINDEX | ID: biblio-827927

ABSTRACT

As lesões em membros de grandes animais são um desafio para médicos veterinários, uma vez que somente a osteossíntese não garante resultados satisfatórios. Muitos pesquisadores vêm se dedicando ao desenvolvimento e estudo de substitutos ósseos produzidos de materiais naturais, como quitosana, colágeno e hidroxiapatita, que auxiliam na regeneração óssea. Seis ovinos fêmeas da raça Santa Inês foram submetidos a ostectomias unicorticais de sete milímetros de diâmetro na região proximal da superfície dorsomedial dos III/IV metacarpianos. Foi implantado compósito de quitosana, colágeno e hidroxiapatita em um membro torácico para avaliação da biocompatibilidade do material ao tecido ósseo ovino, e no membro contralateral foi reproduzida a mesma técnica, porém foi mantido sem preenchimento, como controle. Após 60 dias do procedimento cirúrgico, realizou-se biópsia óssea na área de interface entre biomaterial/osso (membro com compósito) e tecido neoformado/osso (membro controle), para realização de avaliação histológica do material não descalcificado, por meio de microscopia de luz e microscopia eletrônica de varredura. Na análise histomorfométrica, mediante microscopia de luz, foi possível identificar maior porcentagem de tecido neoformado em membro controle, quando comparado ao membro com compósito (80% e 63,5%, respectivamente; P<0,05). Por meio da microscopia eletrônica de varredura, observou-se invasão da estrutura interna do compósito por tecido ósseo neoformado. Não houve formação de tecido cicatricial, reação de corpo estranho ou resposta inflamatória crônica nas amostras analisadas. Conclui-se que o compósito de quitosana, colágeno e hidroxiapatita, quando implantado em tecido ósseo ovino, apresenta biocompatibilidade e perfil osteocondutor.(AU)


Fracture management poses a great challenge to large animal practitioners. Osteosynthesis alone is often insufficient to provide satisfactory outcomes in large animals; therefore, several research efforts have been made to investigate and develop bone substitutes capable of promoting bone regeneration. Chitosan-collagen-hydroxyapatite composites constitute a promising alternative given their similar composition to bone. Six Santa Inês ewes were submitted to the creation of experimental 7mm wide unicortical defects on the dorsomedial aspect of the proximal III/IV metacarpal bone diaphysis. Limbs were randomly selected for treatment with chitosan-collagen-hydroxyapatite composite or to serve as untreated controls. Biopsy fragments were collected from the bone/new bone or the bone/biomaterial interface (control and treated defects respectively) within 60 days of surgery; composite biocompatibility was assessed using light and scanning electron microscopy. Histomorphometric analysis under light microscopy revealed greater percentage of new bone tissue in control compared to treated defects (80% and 63.5% respectively; P<0.05). No scar tissue formation, foreign body or chronic inflammatory reactions were observed. Scanning electron microscopy revealed invasion of the composite by new bone tissue. The chitosan-collagen-hydroxyapatite composite studied is biocompatible with bone and shows osteoconductive properties in sheep.


Subject(s)
Animals , Biocompatible Materials/analysis , Bone and Bones , Bone Substitutes/analysis , Sheep , Bone Regeneration , Chitosan/therapeutic use , Collagen/therapeutic use , Hydroxyapatites , Microscopy, Electron, Scanning/veterinary
3.
Arq. bras. med. vet. zootec ; 60(3): 559-565, jun. 2008. ilus
Article in Portuguese | LILACS | ID: lil-487899

ABSTRACT

Este trabalho visou à ressecção de fragmento dorsocaudal do lobo pulmonar caudal esquerdo com o auxílio de sutura mecânica por via toracoscópica. Foram utilizados 10 eqüinos clinicamente sadios, os quais foram sedados e mantidos em estação. O procedimento foi realizado no hemitórax esquerdo, por três acessos previamente programados: o primeiro acesso foi no 12º espaço intercostal (EIC), o segundo no 14º, 15º ou 16º EIC e o terceiro no 14º ou 15º EIC, conforme a necessidade de posicionamento dos instrumentos. Em todos os animais foi possível controlar o pneumotórax, sendo observada evolução clínica satisfatória durante o período pós-operatório, exceto em um animal. Os resultados obtidos indicam que, por meio da videotoracoscopia, pode-se realizar ressecção pulmonar parcial com uso de sutura mecânica em eqüinos e seu emprego na rotina hospitalar poderá contribuir para melhor compreensão e controle de enfermidades sediadas na cavidade torácica.


In this study, a dorsocaudal portion resection of the left caudal lung lobe was performed using an endoscopic stapler by thoracoscopic procedure. Ten healthy horses, eight males and two females were evaluated by clinical examination and submitted to the surgical procedure. The animals were sedated and maintained in standing position. The procedure was done in the left hemitorax using three access previously studied: the first portal was done at the 12th intercostal space (IS); the second one at the 14th, 15th, or 16th IS; and the third one at the 14th or 15th IS, in accordance with the necessity of positioning the instruments. The employed surgical technique seemed to be adequate in all animals, since it helped controlling the existing pneumothorax; furthermore, clinical recovery during the postoperative period was satisfactory, except for one animal. These results suggest that thoracoscopic may successfully be employed for partial lung resection in horses, using endoscopic staplers, and its practical use may contribute to the knowledge and resolution of thoracic diseases.


Subject(s)
Animals , Equidae , Pneumonectomy/methods , Lung/surgery , Suture Techniques/veterinary , Thoracoscopy/methods
4.
Arq. bras. med. vet. zootec ; 60(2): 315-321, abr. 2008. ilus
Article in Portuguese | LILACS | ID: lil-484654

ABSTRACT

Um eqüino de nove anos de idade apresentou ausência de ar expirado e secreção serossanguinolenta na narina direita, associado a ruído respiratório. Os exames endoscópico e radiológico mostraram uma formação de aproximadamente seis centímetros de diâmetro recoberta por mucosa amarelada, que obstruía a cavidade nasal direita e insinuava-se para a cavidade nasal esquerda. Tal massa foi ressecada por meio de sinusotomia frontal direita. O exame histológico e a cultura revelaram lesão granulomatosa causada por fungos. O tratamento pós-operatório compreendeu associação de antibiótico e antiinflamatório, assim como de lavagens com água destilada e chá de camomila.


A 9-year-old horse presented serosanguineous nasal discharge, absence of breath out through the right nostril, and respiratory noise. Endoscopic and radiographic exams revealed a six centimeter diameter mass, covered by yellowish mucosa, which was obstructing the entire right nasal cavity and part of the left one. The mass was excised through a right frontal sinusotomy. The microscopic exam and the culture revealed a fungic granulomatous rhinitis. Antibiotic and anti-inflammatory drugs were postoperatively administered; moreover, camomile tea and distilled water were flushed in a drain placed above the bone flap.


Subject(s)
Animals , Anti-Bacterial Agents , Anti-Inflammatory Agents , Aspergillosis , Aspergillus , Cryptococcosis , Equidae , Granuloma, Respiratory Tract